Technical Specifications of NSN
Overall Height:
6.500 inches
Body Length:
5.000 inches
Body Height:
3.500 inches
Unthreaded Mounting Hole Diameter:
0.250 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length:
4.000 inches
Operating Tempurature Range:
-60.0/+85.0 degrees celsius
Source Impedance Rating Per Function:
50.0 ohms 1st radio interference
Source Impedance Rating Per Function:
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function:
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function:
50.0 ohms 4th radio interference
Load Impedance Per Function:
50.0 ohms 1st radio interference
Load Impedance Per Function:
50.0 ohms 3rd radio interference
Load Impedance Per Function:
50.0 ohms 2nd radio interference
Load Impedance Per Function:
50.0 ohms 4th radio interference
Power Line Frequency Rating Per Function In Hertz:
60.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz:
60.0 2nd radio interference
Operating Current Rating Per Function In Amps:
25.0 3rd radio interference
Operating Current Rating Per Function In Amps:
25.0 4th radio interference
Operating Current Rating Per Function In Amps:
50.0 1st radio interference
Operating Current Rating Per Function In Amps:
50.0 2nd radio interference
Principal Circuitry Type Per Function:
Capacitance-inductance 1st radio interference
Principal Circuitry Type Per Function:
Capacitance-inductance 2nd radio interference
Principal Circuitry Type Per Function:
Capacitance-inductance 3rd radio interference
Principal Circuitry Type Per Function:
Capacitance-inductance 4th radio interference
Mounting Facility Type And Quantity:
6 unthreaded hole
Functional Terminal Type And Quantity:
4 threaded stud input 1st function
Functional Terminal Type And Quantity:
4 threaded stud output 2nd function
Operating Voltage Rating And Type Per Function:
20.0 volts dc 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function:
20.0 volts dc 4th radio interference 4th function
Operating Voltage Rating And Type Per Function:
230.0 volts ac 1st radio interference 1st function
Operating Voltage Rating And Type Per Function:
230.0 volts ac 2nd radio interference 2nd function
Maximum Dielectric Withstanding Dc Voltage:
500.0 volts at sea level
Body Surface Treatment:
Tin
Style Designator:
Rectangular terminal/terminals on opposite surfaces
Item Name:
Electrical Noise Filter
Other Related Parts
Part Number
Cage
RNCC
RNVC
RNAAC
Status
MSDS
SADC